Agilent 5973N G1099A EI GC Mass Selective Detector

5973N G1099A EI GC/MSD from Agilent

Ref: st5043

Warranty

12 month On-Site Warranty (UK)

Price

£ Please Call

Just In

This Agilent 5973N EI MSD system with 6890 GC (FID) and CTC CombiPAL GC headpsace has been completely re-conditioned and fully configured at our lab here in Kent, and comes with a 12 month warranty and UK installation as standard.

Are you an academic organisation? This system qualifies for a University discount
Enquire for full details...

System Details

Download Autotune Data for Agilent 5973N GC-MSDDownload GC-MSD Autotune Data:

Please take a look at the images above which include tune data.

Complete with an Agilent 6890 Plus GC with split splitless back injector, falme ionisation detector (FID) and CTC CombiPAL GC headspace. It comes with EI source installed.

Mass range
1.6-800 amu in 0.1 amu steps; any subset of this range may be selected by the user.

Scan speed
Instrument provides scan rates up to 5,200 amu/second with 0.1 amu scan step size, with eight sampling rates. (Typical analyses require one scan/second, which is approximately 800 amu/second.)

Dynamic range
Total ADC (analog/digital converter) dynamic range is 106. Linear calibration curves for individual compounds will vary depending on sample, target analyte, experimental conditions, and chromatographic performance.

Communication
LAN

SIM (single ion monitoring) capability
Up to 50 groups of masses, with 30 masses per group, may be switched automatically within an analysis by time-programming during acquisition.

Ionization current
Filament emission current is user-selectable over the range 0-315 μA in all modes of operation. Some combinations of low ionization energy and high emission current are not allowed to avoid damage to the instrument.

Ion source temperature
Temperature of the independently heated ion source can be controlled up to 250°C for EI.

Quadrupole temperature
Temperature of the independently heated quadrupole can be controlled up to 200°C.

Interface temperature
Temperature of the interface (an auxiliary zone of the GC) can be controlled up to 350°C.

High Vacuum Pump Specification
Performance Turbo, Optimal Gas Flow Rate for GC/MS: 4 mL/min

Environmental conditions Temperature
Operating environment: 15 to 35°C at constant temperature (constant temperature: ±2°C per hour)
Non-operating storage temperature: -20 to 70°C

Humidity
Operating: 25% to 50% RH
Non-operating: 10% to 95% RH, (non-condensing)

CTC CombiPAL

The CombiPAL GC sample injection system combines liquid, headspace and SPME injection in one single instrument. This capability allows quick switching from one application to another on the same GC workstation.

Regardless if your samples are processed in headspace, liquid or SPME mode, or if your method requires split/splitless or on column injection, the sampler setup is ready in a few minutes. The CombiPAL provides powerful working capabilities.

Headspace

Robotic vial processing allows straightforward and simple sample analysis. Sample vials are transported into a heated six-position incubator for preconditioning. After they reach equilibrium, a heated gas-tight syringe moves over the incubator and withdraws the headspace sample. After sample injection, the hot syringe is automatically cleaned by purging with inert gas.

Features:

  • Heated syringe: 30°C-150°C selectable in 1°C increments
  • Syringe cleaning: Inert gas purging of heated syringe
  • Syringe sizes: 1.0 ml (0.1-1.0 ml), 2.5 ml (0.25 ml-2.5 ml), 5.0 ml (0.5 ml-5.0 ml)
  • Injection speed: Selectable from 0.01 µl/sec. up to 5 ml/sec.

System Includes:

  • Agilent G1099A 5973N (EI) MSD (Note that the pictures show an HP cover)
  • Agilent G1530N 6890 (FID) Gas Chromatograph
  • CTC CombiPAL GC Headspace Autosampler
  • Independently heated electron-ionization ion source
  • Independently heated hyperbolic quadrupole mass filter
  • High-energy dynode (HED) electron multiplier detector
  • Independently heated GC/MSD interface
  • GC control panel for local monitoring / operation
  • PC, TFT & MassHunter software Version V.07.00 featuring full control and data acquisition
  • 230V Operating voltage
  • UK Installation (please enquire outside of mainland UK)
  • 12 month on-site warranty
Contact Us Here See all 5973s

Servicing & Maintenance

As a continually expanding company Jaytee have a great deal to offer, from service agreements to total instrument portfolio management. Since each client has different requirements, we are able to provide tailored service agreements, whether it be on the instruments you purchase from us, or your own equipment.

Calibration

Jaytee has developed its calibration policy in line with the marketplace and offers a wide range of calibration services. Our clients often require instrument PQ/validation, so we offer a unique approach to this, providing our own calibration package that is specific to your needs.

Enquire / Get A Quote

Fill out the form below to get in touch with us at Jaytee Biosciences:

Contact Us

Interested in Visiting For a Demo:

Interested in FaceTime Demo:

Interested in Renting:



I wish to be contacted by Jaytee Biosciences Ltd regarding this enquiry.

I am happy to be contacted in future by Jaytee Biosciences Ltd in related matters.

Back to Top

Contact Information

Jaytee Biosciences Ltd,
Altira Business Park,
Herne Bay, Kent, CT6 6GZ.
UK.

Phone: +44 (0) 1227 265333

Email: Mailto sales jaytee

Receive a FaceTime demonstration of this MS working

Why employ ms4sale?

Your MS options are far reaching, so why use Jaytee Biosciences? Unlike other providers of used MS equipment, we have the ability to completely:

This is because we employ both skilled engineers and experienced scientists, which allows us to provide a value added solution.

When we acquire an MS system, we are not simply re-listing for sale with a mark-up. We service,test and run the system, producing chromatographic and mass spectral data before we advertise. When our clients ask us whether a particular system is suitable for their application, we provide detailed information, and offer a pre-visit service whereby you send us your sample, which we run and prove for your benefit. Why? Because we can, and because it helps you make the right choices.

Ask yourself why other companies are only showing stock images, with no data or proof of performance - because we have the skills, you get the peace of mind and the ongoing support for your method.

Finally, this is at no added cost, since our pricing policy is flexible, and therefore competitive - a win/win!

Jaytee; No take overs/mergers in over 35 years - just professional, solid, skilled on going support.